Regularly scheduled maintenance is one of the most important steps that you can take to
help ensure a long life for your generator. Our Annual Tune-Up Kit includes the following: - Replacement Generac Air Filter (replace annually)
- Pre-cleaner for the air filter (replace annually)
- Generac Oil filter (replace every 50 hours of operation or annually)
- 2
– Spark plugs - gapped as specified by Generac. (replace annually).
- 2
– Quarts of Briggs & Stratton Synthetic Oil 5-30, specially formulated for air-cooled engines, your generator will
hold approximately 1.7 quarts with a new oil filter. (change every 50 hours of operation or annually).
When performing your maintenance here are some additional
tips: - Run the generator for about 10 minutes to thoroughly warm the
engine prior to draining the oil.
- Drain the oil into a suitable container that can hold 2 quarts of oil - see photo below.
- Remove old oil filter draining
remaining oil from filter into the container - see photo below.
- Place a small amount
of clean oil on the oil filter gasket before hand tightening. After bringing the oil filter snug with
the filter housing, hand tighten another half turn.
- Add 5W30 Fully Synthetic Oil - Briggs & Stratton or equivalent is recommended.
Add oil carefully - see photo below (1.5 to 1.7 quarts for 12 & 15 kW), to much oil will reduce effectiveness of the engine
lubrication system and foul air filter.
- When replacing the air filter, remove any debris
in the air box and make sure that the top of the air box fits securely and locks in place.
- Check
the air intake passages to ensure that they are free of obstruction.
- Check the battery terminals
(see Battery Safety below) to ensure that they are tight and free of corrosion. Adjust battery fluid levels
if applicable.
- Run the generator for about 5 minutes to circulate the new oil in the engine and
new oil filter, then check for oil leaks and the correct oil level. Adjust as necessary.
- Dispose of all waste oil properly. To recycle your old oil ask your favorite full service gas station, the place you
have your oil changed or city or county recyclying centers. We have found all willing to take waste oil.
- While this is the Annual procedure, we recommend
that you check your generator condition initially every month for 3 months after startup, and then every six months
or after every 12 hour power outage thereafter.
- When working on generators safety should be a first priority. We strongly
recommend that you carefully review the manufacturers recommended saftey procedures prior to commencing any service procedures.
We have found that a socket wrench and standard wrench. Generally they are a 5/8" socket and 9/16 wrench on older
models, and 11/16" socket and 5/8" on newer models. The cap will loosen counter clockwise. We have found that bracing the
socket and push down on the wrench works best. The older style loosens slowly while the newer style loosens very quickly (not